ESR Pipette System / ESR Tube
Material: PS
Graduation: 0-190ml, 0-150ml, 0-170ml
Additive: With 3.8% sodium citrate diluents) 0.2ml, With 3.2% sodium citrate diluents) 0.25ml
Cap color: Blue, pink
Closure: With fliter and rubber seal
Package: 100 sets/box, 200 sets/box
Product name:
1) Medmount Medical PS All Type Blood Collection ESR Pipette Tube with CE/ISO
2) Medmount Medical 150mm/170mm/190mm Blood Collection Test ESR Piette Tube with Cap
3) Medmount Medical Products Blood Collection ESR Pipette System for Manual Determination of Erythrocyte Sedimentation Rates
4) Medmount Medical Safety Cap Rubber Blue/ Pink/ Customized Cap ESR Pipette System
5) Medmount Medical PS All Type 3.8% Sodium Citrate ESR Pipette System with Anticoagulation
Product descriptions:
1.For the manual determination of erythrocyte sedimentation rates with ESR stand.
2.Sodium citrate is used as anticoagulant to prevent blood from clotting.
3.Filled with a buffered sodium citrate solution in a concentration of 0.129mol/L (3.8%).
4.The blood to additive ratio is 4:1.
5.After ESR tube has been filled with blood, immediately invert the tube 8-10 times to mix and ensure adequate anticoagulation of the specimen.
Use:
1. Before testing, use a blood sedimentation test (with a built-in 3.8% soalum citrate active) to collect acertain amount of blood samples, mix it with the additives in time, and place it on the horizontally placed Weiss erythrocyte sedimentation rack.
2. Insert the piston end of the ESR Tube slowly and vertically downward into the ESR tube. The seal between the piston and the ESR tube causes the blood sample to slowly rise along the ESR tube and accurately reach the ‘O’ scale to stop the operation. Note: In order to ensure the accuracy of the reading, it must be ensured that the ESR tube touches the bottom of the ESR tube, and the ESR tube remains vertically up right on the Weiss erythrocyte rack.
3. Observe the plasma height in the ESR tube after standing for 1 hour and report the erythrocyte sedimentation value in millimeters of erythrocyte sinking.
4. Safety protection work should be done during the operation. After completing the test, blood samples and consumables should be properly handled to prevent pollution to people and the environment.
Product Parameters:
Product name | ESR Pipette System |
Material | PS |
Graduation | 0-190ml |
Additive | Sodium Citrate 3.8% |
Cap color | Blue, pink, customized |
Closure | With fliter and rubber seal |
Package | 100 sets/box, 200 sets/box |